International Journal of Traditional Chinese Medicine ; (6): 433-435, 2016.
Article in Chinese | WPRIM | ID: wpr-486480

ABSTRACT

Objective To dynamically the preparation process of Huangqi injection and to verify the rationality and existing problems of the process. Methods The preparation was made by the current standard (WS3-B-3335-98) issued by Ministry of Health, and the solid amount of the key processes were measured. The HPLC separation was performed on a Agilent Zorbax Bio-C18 reversed-phase column (250 mm × 4.6 mm, 5μm) in gradient mode of acetonitrile-water with UV detection at 254 nm. The column temperature was kept at 25 ℃, and the flow rate of mobile phase was 1.0 ml/min. Results Solid amounts of different operations of Huangqi injection were measured accurately. The content of the third water extracts was only 6.1%, and the changes of HPLC pointed the content of the 12 peaks of the second peaks decreased obviously. Conclusion The technological rationality of Huangqi injection need to be verified and optimized, the dynamic analysis of HPLC describes the changes of chemical constituents of Huangqi injection qualitatively, which also provides a reference value for establishing its fingerprint.